![]() How long would it reasonably take an 'average' person to travel that extra 3m (under 10ft!!)? The provision of a new escape route would be disproportionate ![]() Detecting the fire as early as possible by fire detection, holding the fire back by compartmentation, providing safe escape routes in which peole can escape quickly by providing emergency lighting and restricting travel distances. I would have to justify getting a very senior officer off the golf course or probably out of the 19th hole and an extra 3m TD is not enoughįire safety is all about time. On its own, an extra 3 metre travel distance on top of the arbitary 18m travel distance in the guides would not be sufficient for an Article 31 prohibition. It would need a risk of fire (poor compartmentation, dodgy and untested electrics) as well as an excessive travel distance. I used to be a Fire Service Inspecting Officer and in my Brigade, what you describe is nowhere near the threshold for a Prohibition Notice. Reinstating the fire escape is going to cost a lot of money and after the last few years of trading during covid its not the best timing. Are there any other steps we can take to reduce the risk (I know its probably difficult to say just by reading a few paragraphs). I would like to know is the fire officer being reasonable in asking us to reinstate the external fire escape? If you think he is can anyone point me in the direction of a good source of supporting information so I can maybe change his mind or his superior. I have spoken to the professional who produced the fire risk assessment since the last fire officer visit but he has advised asking to speak to a superior or getting a solicitor involved (which will probably be expensive). I have read articles about about BS 9999 which seems to be a little more helpful, in that it talks about increasing the travel distance by 15% where a fire alarm is in place but I am not sure if it applies to me as I can’t read the document in full. I have also read Part B of the building regulations for ‘buildings other than dwellings’ and can see anything about extended travel distances in that. The book does say were a fire alarm is in place the travel distance can be extended but he disagrees as he said guest houses need to have a fire alarm. I have read through the sleeping accommodation guide book at great length and it does say where the risk can be reduced the travel distances can be extended but there is nothing definitive in there that I could go back to the fire officer with. ![]() There is an emergency escape plan in place and a Personal Emergency Evacuation Plan. We have a 5 year periodic electrical assessment certificate for the hard wiring, a fire alarm and emergency lighting certificate, the firefighting equipment (extinguishers and fire blanket) is tested every 12 months and a gas certificate every 12 months. Half hour fire doors are in place to all rooms apart from the boiler room that has a 1 hour door and the en-suite bathrooms that are standard doors. The Guest House accommodates 21 guests and has L2 Fire alarm system in place with sounders in every room. The property comprises of a basement, ground, first and second floor. He doesn’t think there is any flexibility in the 18 meter rule and is talking about issuing a prohibition notice so we can’t use the top floor of the building. ![]() He measured the travel distance to be 21 to 22 meters from the furthest point on the top floor of the building. The fire officer disagreed with his colleague and the risk assessor. 2 weeks later the local authority fire officer visited us and said we should carry out the work noted in the fire risk assessment which we did.Ībout 2 weeks ago we had a visit from a different fire officer to carry out an audit of the fire risk assessment. At the time he said we should decommission the fire escape (as its unsafe), provided we upgraded the ceilings in the basement to 2 hours compartmentation, updated the basement doors to half hour fire doors, carry out additional staff training and put a fire escape plan on the back of the bedroom doors as this would reduce the risk and extend the travel distance from 18 meters. In 2019 I had a professional fire risk assessment carried out for my Guest House by an ex fire officer.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |